master1 etcd-Disk Swap Plan

Status: PLAN — still not executed as of 2026-11-12 (captured 2026-05-05). master1 has not been reinstalled and remains the slow etcd voter; the 2026-08-09 raft-timer tuning is the applied stopgap, not the fix (see etcd raft timers). Re-verify the drive model + pricing below before ordering.

Active plan to fix master1's degraded etcd performance by replacing the NVMe under /. Captured 2026-05-05 from a diagnostic session.

Why

master1's etcd is the slow voter and the cause of intermittent apiserver timeouts on this cluster. Confirmed via Prometheus:

10m p99 master1 (192.168.1.9) master2 (192.168.4.9) master3 (192.168.4.10)
etcd_disk_wal_fsync 31 ms 17 ms 16 ms
etcd_disk_backend_commit 103 ms 29 ms 27 ms
etcd_server_slow_apply_total (cumulative) 67,523 21,459 5,738

Read latency on the same NVMe is sub-millisecond. The slowness is on the sync-write path (page cache doesn't help fdatasync). The suspected drive is the budget HS1TBNVME M2 1TB (41% wear at the time), hosting the LVM root that contains /var/lib/etcd.

DANGER — identify drives by model/serial, never by nvmeXn1. master1's NVMe kernel names swap between boots. When this page was written the HS1TBNVME was nvme1n1 and the WD Blue SN570 was nvme0n1; on 2026-11-21 it was the reverse. The WD Blue carries the Ceph OSD (partition 1) and /var/lib/longhorn (partition 2) — pointing a dd/pvmove/wipe at the wrong name destroys production data. Always resolve by stable path first — ls -l /dev/disk/by-id/ | grep -E 'HS1TB|SN570' and pvs -o pv_name,vg_name (cs_master1 must sit on the HS1TBNVME).

  • Replace: HS1TBNVME 1TB, serial 110101000500 (root LVM cs_master1, etcd)
  • Keep: WD Blue SN570 2TB, serial 23172Q802011 (Ceph OSD by-id nvme-WD_Blue_SN570_2TB_23172Q802011_1-part1, Longhorn on part2)

2026-11-21: this drive is also the root cause of the API-VIP flaps — master1's etcd member had 11k slow read-index/14 d vs ~200 on peers (see the kube-vip lease-timing change, #16215).

Cluster has a leader, zero leader changes/hr, no failed proposals — etcd is stable but degraded. Apiserver-master1 takes the brunt because it always reads from local etcd.

Unrelated note: /dev/sdb on master1 is in XfsShutdown state — a secondary SATA disk that fell off the bus. Does not affect etcd (verified: nothing on sdb is mounted; etcd lives on /, OSD-1 lives on the WD Blue's partition 1, Longhorn on its partition 2 — kernel name was nvme0n1 at the time, see the warning above). Investigate on its own schedule.

Drive choice (decided 2026-11-21)

Samsung 990 PRO 1TB (MZ-V9P1T0), M.2 2280, PCIe 4.0, DRAM-cached TLC.

  • Why not the Micron 7450 PRO (PLP): the 2026 NAND crunch priced enterprise PLP M.2 out ($645–913 for 480 GB on 2026-11-21, vs ~$200 in May). Power-loss durability comes from UPS + clean shutdown instead (see Follow-ups); the etcd latency problem is fixed by a DRAM-cached drive, which is what the current budget drive lacks.
  • Slot: both M.2 slots on master1 (ThinkCentre M910x, board 310C) are PCIe 3.0 x4 (Intel 200-series root ports, 8.0 GT/s x4, measured 2026-11-21). A PCIe 4.0/5.0 drive runs at 3.0 — irrelevant for etcd, which needs low-latency fdatasync, not bandwidth. No heatsink variant (does not fit the Tiny chassis).
  • Capacity: / uses ~122 GB; 1 TB is ample.

Why Option B (clone) is out

The new drive is smaller than the old one: the HS1TBNVME is 2,000,409,264 sectors (~1.024 TB); a 990 PRO 1TB is 1,953,525,168 sectors (1.000 TB). The root LV is XFS and fills the disk, and XFS cannot shrink, so a block-level dd/pvmove clone cannot fit. Both M.2 slots are also occupied, so the drives can't be attached side by side without pulling the WD Blue. Reinstall + rejoin (below) is the procedure.

Swap-day procedure

Budget ~3 hours hands-on. Pick a quiet window. master1 is a schedulable control plane, so its workloads move elsewhere during the swap; the RTL-SDR receiver (USB dongle on master1) is down until master1 rejoins.

Single point of failure during the window

From Phase 3 until master1 rejoins, etcd runs on 2 of 2 voters — master2 and master3, both VMs on beast. Any beast hiccup in that window stops the API (running workloads keep running; nothing can be scheduled or changed). Don't do anything to beast during the swap, and don't stretch the window.

Phase 0 — Before swap day (no impact)

  1. Confirm the drive is the 990 PRO (MZ-V9P1T0), not a 990 EVO / EVO Plus (DRAM-less).
  2. Write a CentOS Stream 10 x86_64 installer to USB (master1 runs CS10 today).
  3. Host config capture. A read-only capture of master1's host config (no PKI, no SSH host keys) was taken 2026-11-21 to the operator laptop (~/master1-swap-2026-11/, mode 600 — never commit it): NetworkManager connections (including the VLAN 20/40 sub-interfaces), /etc/crio, /etc/containers (registry mirror config), /etc/sysctl.d, /etc/udev/rules.d (RTL-SDR rules), /etc/yum.repos.d, chrony.conf, fstab, /etc/default/grub, root authorized_keys, the kubelet config, the package list (rpm-names.txt) and enabled units. Re-run it on swap day to catch drift:
ssh root@master1 'cd / && tar czf - --ignore-failed-read \
  --exclude=etc/kubernetes/pki --exclude="etc/ssh/ssh_host_*" \
  etc/NetworkManager/system-connections etc/crio etc/containers \
  etc/sysctl.d etc/modules-load.d etc/udev/rules.d etc/yum.repos.d \
  etc/chrony.conf etc/hosts etc/fstab etc/default/grub etc/sudoers.d \
  root/.ssh/authorized_keys' > ~/master1-swap-2026-11/etc-swapday.tgz

Facts the capture pins down: SELinux disabled, firewalld disabled, no swap, all interfaces DHCP (addresses come from MAC reservations, so they return unchanged), kernel arg initcall_blacklist=simpledrm_platform_driver_init, repos isv_cri-o_stable_v1.36 + kubernetes-1.36, packages cri-o-1.36.3, kubelet/kubeadm/kubectl-1.36.4, iscsi-initiator-utils, nfs-utils, cryptsetup, chrony. /var/lib/longhorn is already mounted by stable path (/dev/disk/by-id/nvme-WD_Blue_SN570_2TB_23172Q802011_1-part2).

Phase 1 — Preflight gates (T-30 min)

Stop if any fails.

Define an etcd helper first (a function, so it also works in zsh, which does not word-split a $E-style variable):

etcdctl2() {
  kubectl -n kube-system exec etcd-master2.${SECRET_DOMAIN} -- etcdctl \
    --endpoints=https://127.0.0.1:2379 --cacert=/etc/kubernetes/pki/etcd/ca.crt \
    --cert=/etc/kubernetes/pki/etcd/peer.crt --key=/etc/kubernetes/pki/etcd/peer.key "$@"
}
kubectl get nodes                                   # all Ready
etcdctl2 endpoint status --cluster -w table         # 3 members, one leader, no errors
for m in master1 master2 master3; do
  echo "$m $(kubectl -n kube-system logs etcd-$m.${SECRET_DOMAIN} --since=1h | grep -c 'took too long')"
done
kubectl rook-ceph ceph status                       # HEALTH_OK, all PGs active+clean
kubectl -n longhorn-system get volumes.longhorn.io  # nothing degraded / rebuilding
flux get ks -A --status-selector ready=false        # empty

The "took too long" counts are never near zero on this cluster. Baseline (2026-11-21, 1 h): master1 ~3.9k, master2 ~2.1k, master3 ~0.7k, with multi-second tails on the two VMs. Proceed if master2/master3 are within ~2x of that baseline and endpoint status shows no errors or recent leader change; postpone if either VM is far above it — they carry etcd alone during the window.

No Longhorn volume has its only replica on master1, and no single-instance CNPG cluster runs there (checked 2026-11-21) — re-check:

# which CNPG primaries sit on master1
kubectl get clusters.postgresql.cnpg.io -A \
  -o jsonpath='{range .items[*]}{.metadata.namespace} {.status.currentPrimary}{"\n"}{end}' |
  while read ns pod; do
    [ "$(kubectl -n "$ns" get pod "$pod" -o jsonpath='{.spec.nodeName}')" = "master1.${SECRET_DOMAIN}" ] && echo "$ns/$pod"
  done

Phase 2 — Snapshot and storage prep

  1. etcd snapshot from a surviving voter, copied off-host:
kubectl -n kube-system exec etcd-master2.${SECRET_DOMAIN} -- etcdctl \
  --endpoints=https://127.0.0.1:2379 \
  --cacert=/etc/kubernetes/pki/etcd/ca.crt \
  --cert=/etc/kubernetes/pki/etcd/peer.crt \
  --key=/etc/kubernetes/pki/etcd/peer.key \
  snapshot save /var/lib/etcd/pre-master1-swap.db
scp root@master2:/var/lib/etcd/pre-master1-swap.db ~/master1-swap-2026-11/
  1. Ceph noout — osd.1 lives on the WD Blue, which stays in the box, so keep Ceph from rebalancing ~2 TB while master1 is down (Rook's own drain handling only holds noout for 30 min):
kubectl rook-ceph ceph osd set noout
  1. Move CNPG primaries off master1 (controlled switchover instead of a drain-time failover). For each primary on master1, promote a replica on another node:
kubectl cnpg status -n databases <cluster>      # pick a healthy replica
kubectl cnpg promote -n databases <cluster> <replica-instance>

Phase 3 — Take master1 out of the cluster

kubectl cordon master1.${SECRET_DOMAIN}
kubectl drain master1.${SECRET_DOMAIN} --ignore-daemonsets \
  --delete-emptydir-data --force --timeout=15m

Remove master1's etcd member from a survivor (do not kubeadm reset master1 — its old drive is kept untouched as a forensic copy):

etcdctl2 member list -w table                 # note master1's member ID
etcdctl2 member remove <master1-member-id>
etcdctl2 endpoint status --cluster -w table    # 2 members, a leader
kubectl delete node master1.${SECRET_DOMAIN}
ssh root@master1 poweroff

kube-vip moves the VIP to a survivor within ~17 s if master1 held it.

Phase 4 — Hardware

  1. Remove the HS1TBNVME (read the label — serial 110101000500). Leave the WD Blue SN570 in its slot, untouched (Ceph OSD + Longhorn).
  2. Fit the 990 PRO (no heatsink) in the freed slot.
  3. Label the old drive "master1 old root — DO NOT BOOT ON THE NETWORK": booted, it would re-register as master1 with a removed etcd member. Keep it ~2 weeks as a forensic copy, then wipe.

Phase 5 — Install CentOS Stream 10

  1. In the installer, select only the Samsung 990 PRO as the install target. Deselect the WD Blue — selecting it wipes the Ceph OSD and Longhorn.
  2. Automatic LVM partitioning is fine; delete the swap LV (or don't create one). Hostname master1.${SECRET_DOMAIN}. Network: DHCP on the onboard NIC (the reservation returns the same address).
  3. After first boot, restore from the capture (extract to a temp dir and copy the specific files — don't blindly overwrite /etc):
  4. etc/NetworkManager/system-connections/vlan-*.nmconnection → /etc/NetworkManager/system-connections/ (mode 600), then nmcli con reload && nmcli con up vlan-enp0s31f6.20 && nmcli con up vlan-enp0s31f6.40
  5. etc/yum.repos.d/isv_cri-o_stable_v1.36.repo, kubernetes-1.36.repo
  6. etc/containers/registries.conf + registries.conf.d/, etc/crio/crio.conf.d/10-crio.conf
  7. etc/sysctl.d/*, etc/udev/rules.d/*rtl*, etc/chrony.conf, root/.ssh/authorized_keys
  8. the /var/lib/longhorn line from the captured etc/fstab
  9. Host settings:
sed -i 's/^SELINUX=.*/SELINUX=disabled/' /etc/selinux/config
systemctl disable --now firewalld
grubby --update-kernel=ALL --args="initcall_blacklist=simpledrm_platform_driver_init"
dnf install -y cri-o-1.36.3 kubelet-1.36.4 kubeadm-1.36.4 kubectl-1.36.4 \
  iscsi-initiator-utils nfs-utils cryptsetup chrony
systemctl enable --now crio iscsid chronyd
systemctl enable kubelet
mkdir -p /var/lib/longhorn && mount -a && ls /var/lib/longhorn/longhorn-disk.cfg
sysctl --system
reboot

Compare rpm -qa --qf '%{NAME}\n' | sort against the captured rpm-names.txt for anything else that matters (e.g. nvme-cli). 5. Prove the fix before joining — etcd's own disk test on the new drive (the 99th-percentile fdatasync should be < 10 ms; the old drive ran ~30 ms):

dnf install -y fio && mkdir -p /var/lib/etcd-fio
fio --name=etcd --directory=/var/lib/etcd-fio --rw=write --ioengine=sync \
  --fdatasync=1 --size=22m --bs=2300

Phase 6 — Rejoin as a control plane

  1. Join material from a survivor:
CERT=$(ssh root@master2 'kubeadm init phase upload-certs --upload-certs' | tail -1)
JOIN=$(ssh root@master2 'kubeadm token create --print-join-command')
ssh root@master1 "$JOIN --control-plane --certificate-key $CERT"

If upload-certs wants a config, render init/clusterconfiguration.yaml with envsubst and pass --config, as init/create-cluster.sh does. The joining node builds its control-plane manifests from the kubeadm-config ConfigMap, so cluster-wide settings (e.g. the apiserver GOMEMLIMIT) come back automatically. 2. Do not add a kube-vip static pod. kube-vip is a DaemonSet on control-plane nodes; it schedules onto master1 by itself. 3. master1 is a schedulable control plane — remove the taint and restore the one manual label (NFD / the Intel GPU plugin re-publish the rest):

kubectl taint nodes master1.${SECRET_DOMAIN} node-role.kubernetes.io/control-plane:NoSchedule-
kubectl label nodes master1.${SECRET_DOMAIN} node.longhorn.io/create-default-disk=true
  1. Check: etcdctl2 member list shows 3 started members; kubectl get csr has nothing stuck Pending.

Phase 7 — Storage back in service

kubectl -n rook-ceph get pods -o wide | grep -E 'osd-prepare|osd-1'   # osd.1 re-activated on master1
kubectl rook-ceph ceph osd tree                                      # osd.1 up/in
kubectl rook-ceph ceph osd unset noout
kubectl rook-ceph ceph status                                        # HEALTH_OK, active+clean
kubectl -n longhorn-system get nodes.longhorn.io master1.${SECRET_DOMAIN}   # Ready, disk schedulable
kubectl get clusters.postgresql.cnpg.io -A                           # all healthy

Phase 8 — Verify the fix

  • master1 etcd WAL fsync p99 < 10 ms (was ~30 ms); backend-commit p99 in line with master2/3; etcd_server_slow_read_indexes_total on master1 growing at the peers' rate.
  • No kube-vip restarts; KubeVipLeaderChurn quiet.
  • RTL-SDR receiver pod back on master1; flux get ks -A clean.

Rollback

  • Before the etcd member remove: kubectl uncordon master1 — done.
  • After it: keep going forward. The cluster is fine on 2 voters for hours (the beast SPOF is the only exposure), so a failed install or join can simply be retried. Don't put the old drive back: its etcd member is gone and it would re-register a conflicting master1.
  • Worst case (etcd lost): restore from the Phase 2 snapshot per Cluster Rebuild.

Sequencing constraints

Before doing either replacement option, confirm:

  1. Cluster is otherwise healthy. Same gating conditions as the Promote Worker to Control Plane preconditions — etcd voter health, Ceph HEALTH_OK, no in-flight long storage operations.
  2. Etcd snapshot saved off-host. See the Etcd snapshot section of the same runbook.
  3. Immich offsite seed finished 2026-05-05 (5-file sample round-trip verified the same day). Paperless seed also finished 2026-05-05 (778 MiB across docs + DB). This gating constraint is resolved — the drive swap no longer needs to coordinate around the initial seed. See offsite_recovery.md.

After master1 is fixed

In order:

  1. Verify the fix landed. master1's etcd slow_apply_total should grow at the same rate as the other voters over a 10-minute window. If yes, the disk swap solved the etcd problem.
  2. Investigate BLUESTORE_SLOW_OP_ALERT on OSD-1. Separate issue, on the WD Blue SN570. Likely Longhorn ↔ Ceph contention on the same drive. Quantify with iostat and Ceph perf counters before deciding what to do.
  3. Then promote worker2 as a control plane per Promote Worker to Control Plane, retiring the VM master2.
  4. Then repeat for master3 with another bare-metal worker, so all three control planes live in independent failure domains.

Follow-ups

  • UPS clean shutdown for master1. The 990 PRO has no power-loss protection, so a hard power cut mid-write is the remaining etcd risk (no worse than the old drive). No host in the cluster runs NUT today; master1 can run nut with the snmp-ups driver against its UPS's network card and power off cleanly on low battery.
  • Multi-second applies on the VM masters. On 2026-11-21 master2/master3 showed slow-apply p99 of 4.7 s / 7.3 s (max ~8 s) in one hour, despite WAL fsync p99 ~25 ms, negligible CPU steal and ~24% free memory — likely large read transactions, not disk. Worth a look after the swap: they are 2 of the 3 voters, and both live on beast.