master1 etcd-Disk Swap Plan¶
Status: PLAN — still not executed as of 2026-11-12 (captured 2026-05-05). master1 has not been reinstalled and remains the slow etcd voter; the 2026-08-09 raft-timer tuning is the applied stopgap, not the fix (see etcd raft timers). Re-verify the drive model + pricing below before ordering.
Active plan to fix master1's degraded etcd performance by replacing
the NVMe under /. Captured 2026-05-05 from a diagnostic session.
Why¶
master1's etcd is the slow voter and the cause of intermittent apiserver timeouts on this cluster. Confirmed via Prometheus:
| 10m p99 | master1 (192.168.1.9) | master2 (192.168.4.9) | master3 (192.168.4.10) |
|---|---|---|---|
etcd_disk_wal_fsync |
31 ms | 17 ms | 16 ms |
etcd_disk_backend_commit |
103 ms | 29 ms | 27 ms |
etcd_server_slow_apply_total (cumulative) |
67,523 | 21,459 | 5,738 |
Read latency on the same NVMe is sub-millisecond. The slowness is on
the sync-write path (page cache doesn't help fdatasync). The
suspected drive is the budget HS1TBNVME M2 1TB (41% wear at the
time), hosting the LVM root that contains /var/lib/etcd.
DANGER — identify drives by model/serial, never by
nvmeXn1. master1's NVMe kernel names swap between boots. When this page was written the HS1TBNVME wasnvme1n1and the WD Blue SN570 wasnvme0n1; on 2026-11-21 it was the reverse. The WD Blue carries the Ceph OSD (partition 1) and/var/lib/longhorn(partition 2) — pointing add/pvmove/wipe at the wrong name destroys production data. Always resolve by stable path first —ls -l /dev/disk/by-id/ | grep -E 'HS1TB|SN570'andpvs -o pv_name,vg_name(cs_master1must sit on the HS1TBNVME).
- Replace: HS1TBNVME 1TB, serial
110101000500(root LVMcs_master1, etcd)- Keep: WD Blue SN570 2TB, serial
23172Q802011(Ceph OSD by-idnvme-WD_Blue_SN570_2TB_23172Q802011_1-part1, Longhorn on part2)2026-11-21: this drive is also the root cause of the API-VIP flaps — master1's etcd member had 11k slow read-index/14 d vs ~200 on peers (see the kube-vip lease-timing change, #16215).
Cluster has a leader, zero leader changes/hr, no failed proposals — etcd is stable but degraded. Apiserver-master1 takes the brunt because it always reads from local etcd.
Unrelated note: /dev/sdb on master1 is in XfsShutdown state — a
secondary SATA disk that fell off the bus. Does not affect etcd
(verified: nothing on sdb is mounted; etcd lives on /, OSD-1 lives
on the WD Blue's partition 1, Longhorn on its partition 2 — kernel name
was nvme0n1 at the time, see the warning above). Investigate on its
own schedule.
Drive choice (decided 2026-11-21)¶
Samsung 990 PRO 1TB (MZ-V9P1T0), M.2 2280, PCIe 4.0, DRAM-cached TLC.
- Why not the Micron 7450 PRO (PLP): the 2026 NAND crunch priced enterprise PLP M.2 out ($645–913 for 480 GB on 2026-11-21, vs ~$200 in May). Power-loss durability comes from UPS + clean shutdown instead (see Follow-ups); the etcd latency problem is fixed by a DRAM-cached drive, which is what the current budget drive lacks.
- Slot: both M.2 slots on master1 (ThinkCentre M910x, board 310C) are
PCIe 3.0 x4 (Intel 200-series root ports, 8.0 GT/s x4, measured
2026-11-21). A PCIe 4.0/5.0 drive runs at 3.0 — irrelevant for etcd, which
needs low-latency
fdatasync, not bandwidth. No heatsink variant (does not fit the Tiny chassis). - Capacity:
/uses ~122 GB; 1 TB is ample.
Why Option B (clone) is out¶
The new drive is smaller than the old one: the HS1TBNVME is
2,000,409,264 sectors (~1.024 TB); a 990 PRO 1TB is 1,953,525,168 sectors
(1.000 TB). The root LV is XFS and fills the disk, and XFS cannot shrink,
so a block-level dd/pvmove clone cannot fit. Both M.2 slots are also
occupied, so the drives can't be attached side by side without pulling the
WD Blue. Reinstall + rejoin (below) is the procedure.
Swap-day procedure¶
Budget ~3 hours hands-on. Pick a quiet window. master1 is a schedulable control plane, so its workloads move elsewhere during the swap; the RTL-SDR receiver (USB dongle on master1) is down until master1 rejoins.
Single point of failure during the window
From Phase 3 until master1 rejoins, etcd runs on 2 of 2 voters — master2 and master3, both VMs on beast. Any beast hiccup in that window stops the API (running workloads keep running; nothing can be scheduled or changed). Don't do anything to beast during the swap, and don't stretch the window.
Phase 0 — Before swap day (no impact)¶
- Confirm the drive is the 990 PRO (MZ-V9P1T0), not a 990 EVO / EVO Plus (DRAM-less).
- Write a CentOS Stream 10 x86_64 installer to USB (master1 runs CS10 today).
- Host config capture. A read-only capture of master1's host config
(no PKI, no SSH host keys) was taken 2026-11-21 to the operator laptop
(
~/master1-swap-2026-11/, mode 600 — never commit it): NetworkManager connections (including the VLAN 20/40 sub-interfaces),/etc/crio,/etc/containers(registry mirror config),/etc/sysctl.d,/etc/udev/rules.d(RTL-SDR rules),/etc/yum.repos.d,chrony.conf,fstab,/etc/default/grub, rootauthorized_keys, the kubelet config, the package list (rpm-names.txt) and enabled units. Re-run it on swap day to catch drift:
ssh root@master1 'cd / && tar czf - --ignore-failed-read \
--exclude=etc/kubernetes/pki --exclude="etc/ssh/ssh_host_*" \
etc/NetworkManager/system-connections etc/crio etc/containers \
etc/sysctl.d etc/modules-load.d etc/udev/rules.d etc/yum.repos.d \
etc/chrony.conf etc/hosts etc/fstab etc/default/grub etc/sudoers.d \
root/.ssh/authorized_keys' > ~/master1-swap-2026-11/etc-swapday.tgz
Facts the capture pins down: SELinux disabled, firewalld
disabled, no swap, all interfaces DHCP (addresses come from
MAC reservations, so they return unchanged), kernel arg
initcall_blacklist=simpledrm_platform_driver_init, repos
isv_cri-o_stable_v1.36 + kubernetes-1.36, packages
cri-o-1.36.3, kubelet/kubeadm/kubectl-1.36.4,
iscsi-initiator-utils, nfs-utils, cryptsetup, chrony.
/var/lib/longhorn is already mounted by stable path
(/dev/disk/by-id/nvme-WD_Blue_SN570_2TB_23172Q802011_1-part2).
Phase 1 — Preflight gates (T-30 min)¶
Stop if any fails.
Define an etcd helper first (a function, so it also works in zsh, which
does not word-split a $E-style variable):
etcdctl2() {
kubectl -n kube-system exec etcd-master2.${SECRET_DOMAIN} -- etcdctl \
--endpoints=https://127.0.0.1:2379 --cacert=/etc/kubernetes/pki/etcd/ca.crt \
--cert=/etc/kubernetes/pki/etcd/peer.crt --key=/etc/kubernetes/pki/etcd/peer.key "$@"
}
kubectl get nodes # all Ready
etcdctl2 endpoint status --cluster -w table # 3 members, one leader, no errors
for m in master1 master2 master3; do
echo "$m $(kubectl -n kube-system logs etcd-$m.${SECRET_DOMAIN} --since=1h | grep -c 'took too long')"
done
kubectl rook-ceph ceph status # HEALTH_OK, all PGs active+clean
kubectl -n longhorn-system get volumes.longhorn.io # nothing degraded / rebuilding
flux get ks -A --status-selector ready=false # empty
The "took too long" counts are never near zero on this cluster.
Baseline (2026-11-21, 1 h): master1 ~3.9k, master2 ~2.1k, master3 ~0.7k,
with multi-second tails on the two VMs. Proceed if master2/master3 are
within ~2x of that baseline and endpoint status shows no errors or recent
leader change; postpone if either VM is far above it — they carry etcd
alone during the window.
No Longhorn volume has its only replica on master1, and no single-instance CNPG cluster runs there (checked 2026-11-21) — re-check:
# which CNPG primaries sit on master1
kubectl get clusters.postgresql.cnpg.io -A \
-o jsonpath='{range .items[*]}{.metadata.namespace} {.status.currentPrimary}{"\n"}{end}' |
while read ns pod; do
[ "$(kubectl -n "$ns" get pod "$pod" -o jsonpath='{.spec.nodeName}')" = "master1.${SECRET_DOMAIN}" ] && echo "$ns/$pod"
done
Phase 2 — Snapshot and storage prep¶
- etcd snapshot from a surviving voter, copied off-host:
kubectl -n kube-system exec etcd-master2.${SECRET_DOMAIN} -- etcdctl \
--endpoints=https://127.0.0.1:2379 \
--cacert=/etc/kubernetes/pki/etcd/ca.crt \
--cert=/etc/kubernetes/pki/etcd/peer.crt \
--key=/etc/kubernetes/pki/etcd/peer.key \
snapshot save /var/lib/etcd/pre-master1-swap.db
scp root@master2:/var/lib/etcd/pre-master1-swap.db ~/master1-swap-2026-11/
- Ceph
noout— osd.1 lives on the WD Blue, which stays in the box, so keep Ceph from rebalancing ~2 TB while master1 is down (Rook's own drain handling only holdsnooutfor 30 min):
- Move CNPG primaries off master1 (controlled switchover instead of a drain-time failover). For each primary on master1, promote a replica on another node:
kubectl cnpg status -n databases <cluster> # pick a healthy replica
kubectl cnpg promote -n databases <cluster> <replica-instance>
Phase 3 — Take master1 out of the cluster¶
kubectl cordon master1.${SECRET_DOMAIN}
kubectl drain master1.${SECRET_DOMAIN} --ignore-daemonsets \
--delete-emptydir-data --force --timeout=15m
Remove master1's etcd member from a survivor (do not kubeadm reset
master1 — its old drive is kept untouched as a forensic copy):
etcdctl2 member list -w table # note master1's member ID
etcdctl2 member remove <master1-member-id>
etcdctl2 endpoint status --cluster -w table # 2 members, a leader
kubectl delete node master1.${SECRET_DOMAIN}
ssh root@master1 poweroff
kube-vip moves the VIP to a survivor within ~17 s if master1 held it.
Phase 4 — Hardware¶
- Remove the HS1TBNVME (read the label — serial
110101000500). Leave the WD Blue SN570 in its slot, untouched (Ceph OSD + Longhorn). - Fit the 990 PRO (no heatsink) in the freed slot.
- Label the old drive "master1 old root — DO NOT BOOT ON THE NETWORK":
booted, it would re-register as
master1with a removed etcd member. Keep it ~2 weeks as a forensic copy, then wipe.
Phase 5 — Install CentOS Stream 10¶
- In the installer, select only the Samsung 990 PRO as the install target. Deselect the WD Blue — selecting it wipes the Ceph OSD and Longhorn.
- Automatic LVM partitioning is fine; delete the swap LV (or don't
create one). Hostname
master1.${SECRET_DOMAIN}. Network: DHCP on the onboard NIC (the reservation returns the same address). - After first boot, restore from the capture (extract to a temp dir and
copy the specific files — don't blindly overwrite
/etc): etc/NetworkManager/system-connections/vlan-*.nmconnection→/etc/NetworkManager/system-connections/(mode 600), thennmcli con reload && nmcli con up vlan-enp0s31f6.20 && nmcli con up vlan-enp0s31f6.40etc/yum.repos.d/isv_cri-o_stable_v1.36.repo,kubernetes-1.36.repoetc/containers/registries.conf+registries.conf.d/,etc/crio/crio.conf.d/10-crio.confetc/sysctl.d/*,etc/udev/rules.d/*rtl*,etc/chrony.conf,root/.ssh/authorized_keys- the
/var/lib/longhornline from the capturedetc/fstab - Host settings:
sed -i 's/^SELINUX=.*/SELINUX=disabled/' /etc/selinux/config
systemctl disable --now firewalld
grubby --update-kernel=ALL --args="initcall_blacklist=simpledrm_platform_driver_init"
dnf install -y cri-o-1.36.3 kubelet-1.36.4 kubeadm-1.36.4 kubectl-1.36.4 \
iscsi-initiator-utils nfs-utils cryptsetup chrony
systemctl enable --now crio iscsid chronyd
systemctl enable kubelet
mkdir -p /var/lib/longhorn && mount -a && ls /var/lib/longhorn/longhorn-disk.cfg
sysctl --system
reboot
Compare rpm -qa --qf '%{NAME}\n' | sort against the captured
rpm-names.txt for anything else that matters (e.g. nvme-cli).
5. Prove the fix before joining — etcd's own disk test on the new drive
(the 99th-percentile fdatasync should be < 10 ms; the old drive ran
~30 ms):
dnf install -y fio && mkdir -p /var/lib/etcd-fio
fio --name=etcd --directory=/var/lib/etcd-fio --rw=write --ioengine=sync \
--fdatasync=1 --size=22m --bs=2300
Phase 6 — Rejoin as a control plane¶
- Join material from a survivor:
CERT=$(ssh root@master2 'kubeadm init phase upload-certs --upload-certs' | tail -1)
JOIN=$(ssh root@master2 'kubeadm token create --print-join-command')
ssh root@master1 "$JOIN --control-plane --certificate-key $CERT"
If upload-certs wants a config, render init/clusterconfiguration.yaml
with envsubst and pass --config, as init/create-cluster.sh does.
The joining node builds its control-plane manifests from the
kubeadm-config ConfigMap, so cluster-wide settings (e.g. the
apiserver GOMEMLIMIT) come back automatically.
2. Do not add a kube-vip static pod. kube-vip is a DaemonSet on
control-plane nodes; it schedules onto master1 by itself.
3. master1 is a schedulable control plane — remove the taint and restore
the one manual label (NFD / the Intel GPU plugin re-publish the rest):
kubectl taint nodes master1.${SECRET_DOMAIN} node-role.kubernetes.io/control-plane:NoSchedule-
kubectl label nodes master1.${SECRET_DOMAIN} node.longhorn.io/create-default-disk=true
- Check:
etcdctl2 member listshows 3 started members;kubectl get csrhas nothing stuck Pending.
Phase 7 — Storage back in service¶
kubectl -n rook-ceph get pods -o wide | grep -E 'osd-prepare|osd-1' # osd.1 re-activated on master1
kubectl rook-ceph ceph osd tree # osd.1 up/in
kubectl rook-ceph ceph osd unset noout
kubectl rook-ceph ceph status # HEALTH_OK, active+clean
kubectl -n longhorn-system get nodes.longhorn.io master1.${SECRET_DOMAIN} # Ready, disk schedulable
kubectl get clusters.postgresql.cnpg.io -A # all healthy
Phase 8 — Verify the fix¶
- master1 etcd WAL fsync p99 < 10 ms (was ~30 ms); backend-commit p99
in line with master2/3;
etcd_server_slow_read_indexes_totalon master1 growing at the peers' rate. - No kube-vip restarts;
KubeVipLeaderChurnquiet. - RTL-SDR receiver pod back on master1;
flux get ks -Aclean.
Rollback¶
- Before the etcd
member remove:kubectl uncordon master1— done. - After it: keep going forward. The cluster is fine on 2 voters for
hours (the beast SPOF is the only exposure), so a failed install or join
can simply be retried. Don't put the old drive back: its etcd member is
gone and it would re-register a conflicting
master1. - Worst case (etcd lost): restore from the Phase 2 snapshot per Cluster Rebuild.
Sequencing constraints¶
Before doing either replacement option, confirm:
- Cluster is otherwise healthy. Same gating conditions as the Promote Worker to Control Plane preconditions — etcd voter health, Ceph HEALTH_OK, no in-flight long storage operations.
- Etcd snapshot saved off-host. See the Etcd snapshot section of the same runbook.
- Immich offsite seed finished 2026-05-05 (5-file sample
round-trip verified the same day). Paperless seed also finished
2026-05-05 (778 MiB across docs + DB). This gating constraint is
resolved — the drive swap no longer needs to coordinate around the
initial seed. See
offsite_recovery.md.
After master1 is fixed¶
In order:
- Verify the fix landed. master1's etcd
slow_apply_totalshould grow at the same rate as the other voters over a 10-minute window. If yes, the disk swap solved the etcd problem. - Investigate
BLUESTORE_SLOW_OP_ALERTon OSD-1. Separate issue, on the WD Blue SN570. Likely Longhorn ↔ Ceph contention on the same drive. Quantify withiostatand Ceph perf counters before deciding what to do. - Then promote worker2 as a control plane per Promote Worker to Control Plane, retiring the VM master2.
- Then repeat for master3 with another bare-metal worker, so all three control planes live in independent failure domains.
Follow-ups¶
- UPS clean shutdown for master1. The 990 PRO has no power-loss
protection, so a hard power cut mid-write is the remaining etcd risk
(no worse than the old drive). No host in the cluster runs NUT today;
master1 can run
nutwith thesnmp-upsdriver against its UPS's network card and power off cleanly on low battery. - Multi-second applies on the VM masters. On 2026-11-21 master2/master3 showed slow-apply p99 of 4.7 s / 7.3 s (max ~8 s) in one hour, despite WAL fsync p99 ~25 ms, negligible CPU steal and ~24% free memory — likely large read transactions, not disk. Worth a look after the swap: they are 2 of the 3 voters, and both live on beast.